9. PCV VALVE INSTALLATION
A. Locate the valve cover vent hose attached
between the intake manifold and the rear of
the valve cover.
B. Remove the factory 90° rubber reducer from
the line where it attaches to the valve cover
and discard.
C. Locate the PCV valve assembly
(4GN139-096). See Fig. 9-a
D. Assemble the PCV valve assembly as seen
in figure 9-b
E.
Install the previously assembled PCV valve
assembly and secure using the supplied
hose clamps. See Fig. 9-c
F.
Install the 1/2” plastic hose union (7PP500-
001) into the open end of the factory valve
cover vent hose previously connected to the
factory air inlet assembly. See Fig 9-d
G. Connect the 1/2” diameter 1.25” long hose
provided between the previously installed
hose union and the 1/2” x 90° install in the
90° inlet duct. See Fig 9-d , 9-e
Fig. 9-a
Fig. 9-b
Fig. 9-c
Fig 9-e