7 SERIES 50Hz 700A11 INSTALLATION MANUAL

Wiring Schematics cont.

Aurora Variable Speed cont.

02/15/13

97P842-11A

PB2

Violet

Blue

With optional ' EA' Series

2

3

HE1

TS1

HE2

TS2

HE3

TS3

HE4

TS4

Pink

Yellow
Black

Gray

Pink

Yellow

Black

Gray

Gray

Yellow

Pink

Black

Pink

Yellow

Black

Gray

Green

P9

ER1

ER2

ER3

ER4

NO

NO

NO

NO

Brown

Orange

5

4

EA Series PCB

P1

P2

1

L2

L1

L2

L1

G

G

Circuit 1

Circuit 2

NOTE 3

220-240/50/1

220-240/50/1

Auxiliary Electric Heat Power

Green

Typical schematic shown

Auxiliary ElectricHeat

ECM

Blower
Motor

P11

2

3

4

5

1

P12

16 1

12 15 10

PWM

C1

C2

R

G

33

CFM

C

1

2

3

4

L1

L2

Single Disconnect Power

220-240/50/1

Aux Elect Power

220-240/50/1

L1

L2

L1

L2

Unit Power

220-240/50/1

CSA installed units only

Local codes may require a single

source of power supply

Breaker box
furnished by

installer

Circuit Breakers

F

P13

CFM

C

3

PWM

P13 on ABC Board

P3 on ABC Board

P3

EH2

C EH1 C

CO

Condensate

Brown

Orange

G

G

G

G

C

1

2

3

4

EA Staging
NOTE 5

NO

COM

K6 Relay

Connects to L2
and NO on
AXB Board

L2

Figure 1:

Optional Internal

Hot Water

Generation Pump

Wiring Schematic

DHW

Pump

Blue

Blue

Cabinet

HW

Switch

3

2

1

Purple

Notes

3 - Use manufacturer’s part number 19P592-01 (jumper bar assembly)
when single source power is required.

1 - Switch blue and red wires for 220V operation.

2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed

4 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
5 - For additional Auxiliary Heat staging place jumpers as shown.

6 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
7 – When Auxiliary Heat is field installed the harness will then be connected to
the auxiliary heat unit. The auxiliary heat unit will then power the blower. Refer to
EAS/EAM/EAL Auxiliary Heat kit installation instructions.

8 – Brown blower power wire routed through Current Transducer two times.

9 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.

10 – Communication cable routed through Ferrite Toroid four times.

11 – Compressor power cable routed through Ferrite Toroid three times.

12 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.