POWER SUPPLY

Insert the connector end of the

Power Cord into

the

Power Cord Port on the right side of the unit.

Insert the

Plug on the Power Cord into a standard

120-volt grounded electrical outlet (Figure 2). DO

NOT modify the plug to fit an unsuitable outlet.

Power Cord

Port

Connector

End

Plug End

GROUNDING

This appliance must be grounded while in use to

protect the operator from electrical shock. The

appliance is equipped with a 3-conductor cord

and a 3-prong grounding type plug to fit the proper

grounding-type receptacle. The appliance has a

plug that looks like Figure A. An adaptor, Figure B,

should be used for connecting Figure A plugs to two-

prong receptacles. The grounding tab which extends

from the adaptor must be connected to a permanent

ground such as a properly grounded outlet box as

shown in Figure C using a metal screw.

EXTENSION CORDS

Use only 3-wire extension cords which have 3-prong

grounding-type plugs and a 3-pole cord connector

that accepts the plug from the appliance. Use

only extension cords having an electrical rating not

less than the rating of the appliance. Do not use

damaged extension cords. Examine extension

cord before using and replace if damaged. Do not

abuse extension cord and do not yank on any cord

to disconnect. Keep cord away from heat and sharp

edges.

Figure A

Figure B

Figure C

Circuit

Grounding

Conductor

Grounding

Prong

Metal

Grounding

Screw

Cover of

Grounded

Outlet Box

Grounding

Means

AA2220

GROUNDING INSTRUCTIONS

Power

Cord

Figure 2

WARNING!

Before cleaning, assembling or disassembling the

Vacuum Sealer, make sure the Vacuum Sealer is OFF and the PLUG IS

REMOVED FROM THE OUTLET/POWER SOURCE!

REPLACING THE SEAL BAR TAPE:

*NOTE one extra piece of Seal Bar Tape is included with the original unit as a spare.

1. Turn “OFF” the

Vacuum Sealer and remove the Power Cord from the electrical

outlet.

2. Make sure the unit is completely cool.

3. Open the

Vacuum Lid.

4. Pick at either end of the

Seal Bar Tape covering the Seal Bar Heating Element

until it lifts slightly. Grasp the loose end and slowly pull the

Seal Bar Tape back over

itself until fully removed (Figure 9).

5. Repeat step 4 for the

Seal Bar Tape covering Vacuum Lid Seal. DO NOT remove

the

Seal.

6. Remove the backing from a new wide strip of

Seal Bar Tape for the Seal Bar Heating

Element. Be careful not to allow the Seal Bar Tape to contact anything including itself

while the adhesive side is exposed.

7. Hold one end of the

Seal Bar Tape in each hand. Stick the left end of the Seal Bar

Tape to the flat area on the Plastic Vacuum Chamber just left of the Seal Bar Heating

Element. Apply the Seal Bar Tape from left to right over the Seal Bar Heating Element

until done. Make sure there are no wrinkles or folds in the

Seal Bar Tape once applied.

The

Seal Bar Tape should fully cover the Seal Bar Heating Element.

8. Remove the backing from a new narrow strip of

Seal Bar Tape for the Vacuum Lid

Seal. Stick the left end of the Seal Bar Tape onto the left end of the Seal. The Seal Bar

Tape and Seal ends should be flush. Apply the Seal Bar Tape from left to right over the

Vacuum Lid Seal until done. Make sure there are no wrinkles or folds in the Seal Bar

Tape once applied. The Seal Bar Tape should fully cover the Vacuum Lid Seal.

Upper Seal Bar Tape

Figure 9

Lower Seal Bar Tape

-7-