Wyred 4 Sound STmkII Series User Manual

Page 11

Advertising
background image

pg. 9

regarding a solution. NOTE: We only recommend using a ground isolator for trouble

shooting purposes, and it should be removed after the problem has been found and

resolved. Having the ground of any unit disconnected can potentially create a

dangerous situation.

An easy way to locate a noisy component is to replicate the problem and then

start disconnecting components one at a time, starting with the source end of your

system. Digital cable boxes and satellite receivers are notorious for making ground

loop hum. This is normally caused by the voltage potential on the input wire (shield

side) for either of the boxes when referenced to ground. If this is the case in your

system, the installation of an isolating transformer would be the easiest solution and

they are normally readily available at your local electronics parts store. A better

solution is a power strip with grounded and surge protected F-connectors that you

can pass your cable or satellite signal through.