Specifications

Inputs and outputs: Transformer-isolated, 110-• terminated AES/EBU (3 inputs, 3 outputs)

Sample rates supported: 32 kHz – 96 kHz

Input resolution: up to 24 bits

Output resolution: 16, 20, or 24 bits undithered or TPDF dithered

Compression ratios: 1.1:1 to 8.0:1

Limiter ratio: 100:1

Threshold: from –95.0 dBFS to 0.00 dBFS

Attack time: from 5.0 •s to 950 ms.

Release time: from 5.0 •s to 950 ms.

Highpass filters in detector chains: -12 dB/octave slope w/corner frequency from 10 Hz to 990

Hz

Dynamic range: better than 130 dB

THD + Noise: less than –130 dB

AC Power: 110/220 volts @ 50/60 Hz