Specifications

1

1-5

Table 1-1. Specifications

Maximum Voltage Between any
Terminal and Earth Ground

Rated voltage

Display

Digital: 3,200 counts, updates 2.5/sec
Analog: 31 segments, updates 25/sec

Response Time of Digital Display

V ac < 2 s
V dc < 1 s

< 1s to 320 k

, < 2s to 3.2 M

,

< 10 s to 32 M

Operating Temperature

0

°

C to 50

°

C

Storage Temperature

-40

°

C to 60

°

C

Temperature Coefficient

0.1 x (specified accuracy)/

°

C

(<18

°

C or >28

°

C)

Electromagnetic Compatibility In
RF field of 3 V/m on all functions.

Total accuracy = Specified accuracy
+ 0.1% of range.

Relative Humidity

except 32 M

range

32 M

range only

0% to 90% (0

°

C to 35

°

C)

0% to 70% (35

°

C to 50

°

C)

0% to 80% (0

°

C to 35

°

C)

0% to 70% (35

°

C to 50

°

C)

Altitude

Operating: 2000 meters
Storage: 12,000 meters

Battery Type

9 V NEDA 1604 or 6F22 or 006P,
or NEDA 1604A or 6LR61

Battery Life

2000 hrs typical with alkaline
1600 hrs typical with carbon zinc

Continuity Beeper

4096 Hz

Shock, Vibration

per MIL-T-PRF 28800F Class III, Sinusoidal,
Non Operating

Size (H x W x L)

3.7 cm x 8.9 - 7.8 cm x 19 cm
(1.5 in x 3.5 - 3.1 in x 7.49 in)

Weight

365 g (12.9 oz)

Safety

600 V CAT III and 1000 V CAT II per
ANSI/ISA S82.01-1994, EN 61010-1: 1993,
CSA C22.2 No 1010.1-92, UL 3111-1.

EMC Regulations

EN 61326-1 1997.

Certifications/Listings

Advertising