Extension Cord
Use extension cord if needed. The cord must have

a three-prong, grounding plug and a three-hole

receptacle. Make sure cord is in good shape. It must

be heavy enough to carry the current needed. An un-

dersized cord will cause a drop in line voltage. This

will result in loss of power and overheating. Use a

No. 16 AWG cord for lengths less than 50 feet.

ATTACHING WOOD BASE TO SOLID
FLOOR

For attaching base to solid floors (concrete or

masonry)
Note:

Floor anchors and mounting screws are

in hardware package. The hardware package is

provided with fireplace.
1. Drill holes at marked locations using 5/16"

drill bit. For solid floors (concrete or ma-

sonry), drill at least 1" deep.

2. Fold floor anchor as shown in Figure 22.
3. Insert floor anchor (wings first) into hole. Tap

anchor flush to floor.

4. Insert mounting screws through base and into

floor anchors.

5. Tighten screws until base is firmly fastened to

floor.

INSTALLATION

Continued

Figure 22 - Folding Anchor

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 45° male flare fitting

5/8"-18 UNF (Unified National

Fine Thread) inlet connection and

the flexible gas line provided.

WARNING: A qualified service

person must connect fireplace

to gas supply. Follow all local

codes.

CAUTION: Never connect

propane/LP fireplace directly

to the propane/LP supply. This

fireplace requires an external

regulator (not supplied). Install

the external regulator between

the fireplace and propane/LP

supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

For propane/LP units, installer must supply an

external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14

inches of water. If you do not reduce incoming gas

pressure, fireplace regulator damage could occur.

Install external regulator with the vent pointing

down as shown in Figure 23. Pointing the vent

down protects it from freezing rain or sleet.

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" or greater diameter to allow

proper gas volume to fireplace.

If pipe is too small, undue loss

of volume will occur.

Propane/LP
Supply Tank

Vent Pointing Down

External
Regulator

Figure 23 - External Regulator with Vent

Pointing Down