Installation must include an equipment shutoff

valve, union, and plugged 1/8" NPT tap. Locate NPT

tap within reach for test gauge hook up. NPT tap

must be upstream from fireplace (see Figure 24).
IMPORTANT:

Install an equipment shutoff valve

in an accessible location. The equipment shutoff

valve is for turning on and shutting off the gas to

the appliance.
Check your building codes for any special re-

quirements for locating equipment shutoff valve

to fireplaces.
Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could result

in clogged fireplace valves.

WARNING: Use pipe joint

sealant that is resistant to liq-

uid petroleum (LP) gas.

We recommend that you install a sediment trap in

supply line as shown in Figure 24. Locate sediment

trap where it is within reach for cleaning. Install in

piping system between fuel supply and fireplace.

Locate sediment trap where trapped matter is not

likely to freeze. A sediment trap traps moisture and

contaminants. This keeps them from going into fire-

place controls. If sediment trap is not installed or is

installed wrong, fireplace may not run properly.

INSTALLATION

Continued

* Purchase the optional CSA design-certified

equipment shutoff valve from your dealer. See

Accessories, page 30.

Figure 24 - Gas Connection

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

PROPANE/LP
From External
Regulator (11"
W.C. to 14" W.C.
Pressure)

NATURAL
From Gas Meter
(5" W.C. to 10.5"
W.C. Pressure)

3" Minimum

Pipe

Cap

Tee

Nipple

Joint

Sediment Trap

CONNECTING EQUIPMENT
SHUTOFF VALVE TO HEATER
CONTROL

Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not

provided)

1. Remove fireplace screen. Remove two screws

that hold fireplace screen in place for shipping.

These screws are located near top of screen.

Discard screws. Lift fireplace screen up and

pull out to remove.

2. Remove screws that attach branch support

to fireplace (see Figure 25). Carefully lift up

branch support and remove from fireplace (see

Figure 25).

3. Route flexible gas line, included, from fire-

place control to equipment shutoff valve

through side or rear access holes in outer

casing.

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 25).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

CAUTION: Avoid damage to

regulator. Hold gas regulator

with wrench when connecting it

to gas piping and/or fittings.

Figure 25 - Removing Log Base

Assembly From Fireplace

Branch
Support

Screen

Screen
Shipping
Screw

Shoulder

Screw

Flexible
Gas Line