Desa CGN12 User Manual

Page 18

Advertising
background image

18

REMEDY

1. Turn on gas supply or

open manual shutoff
valve

2. Press in control knob

while turning to PILOT/
IGN position

3. Continue holding down

control knob. Repeat ig-
niting operation until air
is removed

4. Clean ODS/pilot (see

C L E A N I N G A N D
M A I N T E N A N C E ,
page 17) or replace
ODS/pilot assembly

5. Replace gas regulator

1. Press in control knob

fully

2. After ODS/pilot lights,

keep control knob
pressed in 10 seconds

3. Fully open manual shut-

off valve

4. Hand tighten until snug,

then tighten 1/4 turn
more

5. A) Contact local natural

gas company

B) Clean ODS/pilot (see
C L E A N I N G A N D
M A I N T E N A N C E ,
page 17) or replace
ODS/pilot assembly

6. Replace thermocouple

7. Replace control valve

OBSERVED
PROBLEM

When control knob is
pressed in and turned
to the PILOT/IGN po-
sition, there is spark at
ODS/pilot but no igni-
tion

ODS/pilot lights but
flame goes out when
control knob is
released

POSSIBLE
CAUSE

1. Gas supply turned off or

manual shutoff valve
closed

2. Control knob not

pressed in while being
turned to PILOT/IGN
position

3. Air in gas lines when

installed

4. ODS/pilot is clogged

5. Gas regulator setting is

not correct

1. Control knob not fully

pressed in

2. Control knob not

pressed in long enough

3. Manual shutoff valve

not fully open

4. Thermocouple connec-

tion loose at control
valve

5. Pilot flame not touching

thermocouple, which
allows thermocouple to
cool, causing pilot
flame to go out. This
problem could be
caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially
clogged ODS/pilot

6. Thermocouple dam-

aged

7. Control valve damaged

Continued