OBSERVED
PROBLEM

Burner(s) does not
light after ODS/pilot is
lit

Delayed ignition of
burner(s)

Burner backfiring
during combustion

Burner plaque(s) does
not glow

Slight smoke or odor
during initial opera-
tion

Heater produces a
clicking/ticking noise
just after burner is lit or
shut off

REMEDY

1. Clean burner orifice(s)

(see CLEANING AND
MAINTENANCE, page
17) or replace burner
orifice(s)

2. Replace burner orifice(s)

3. Contact local natural gas

company

1. Contact local natural gas

company

2. Clean burner orifice(s)

(see CLEANING AND
MAINTENANCE, page
17) or replace burner
orifice(s)

1. Clean burner orifice(s)

(see CLEANING AND
MAINTENANCE, page
17) or replace burner
orifice(s)

2. Replace burner
3. Replace gas regulator

1. Replace burner
2. Contact local natural gas

company

3. Turn control knob until it

locks at desired setting

1. Problem will stop after a

few hours of operation

1. This is common with

most heaters. If noise is
excessive, contact quali-
fied service person

POSSIBLE
CAUSE

1. Burner orifice(s) is

clogged

2. Burner orifice(s) di-

ameter is too small

3. Inlet gas pressure is too

low

1. Manifold pressure is too

low

2. Burner orifice(s) is

clogged

1. Burner orifice(s) is

clogged or damaged

2. Burner damaged
3. Gas regulator defective

1. Plaque damaged
2. Inlet gas pressure is too

low

3. Control knob set be-

tween locked positions

1. Residues from manu-

facturing processes

1. Metal expanding while

heating or contracting
while cooling

Advertising