Unvented natural gas log heater, Operating heater, Manually-controlled models – Desa CLD3924NT User Manual

Page 16

Advertising
background image

16

104385

UNVENTED NATURAL GAS LOG HEATER

CGS2718N, CGS3124N, CLD3018N,
CLD3924NT, and CCL3930NT(A)

Thermocouple

Figure 31 - Pilot

Ignitor Electrode

Pilot Burner

WARNING: Do not operate

heater between PILOT and HIGH
positions.

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

WARNING:

• If fireplace has glass doors,

never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Also
if fireplace opening has vents
at the bottom, you must open
the vents before operating
heater.

• You must operate this heater

with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.

NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be present.
Open damper or window to vent
smell. This will only last a few hours.

Note:

Home owners generally prefer to

operate their heater with the chimney
damper closed. This will put all the heat
into the room. However, there may be
times you will desire the full flames of the
Hi heat setting but will find the heat output
excessive. You can open the chimney
damper (if you have one) fully or partially
to release some of the heat.

Figure 30 - Control Knob and Ignitor But-
ton Location

PILOT

OFF

LO

HI

Control Knob

Ignitor Button

OPERATING
HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
above.

2.

Make sure manual shutoff valve is
fully open.

3.

Press in and turn control knob clock-
wise

Clockwise

to the OFF position.

WARNING: Damper handle

will be hot if heater has been
running.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation. If you don’t smell gas, go
to the next step.

5.

Slightly depress and turn control knob
counterclockwise

C-clockwise

to the PI-

LOT position. Press in control knob for
five (5) seconds (see Figure 30).

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.

6.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
burner. If needed, keep pressing ig-
nitor button until pilot lights.

Note:

If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure,
page 17.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7.
• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

8.

Slightly depress and turn control
knob counterclockwise

C-clockwise

to

desired heating level. The burner
should light. Set control knob to any
heat level between HI and LO.

Manually-Controlled Models

Advertising
This manual is related to the following products: