SPECIFICATIONS

OPS-ENCLOSED VERSION

OPS-CHASSIS VERSION

Product Number

964404

964403

Input Power Options

+12VDC @ 800 mA
115VAC @ 110 mA
230VAC @ 57 mA

+12VDC @ 800 mA
115VAC @ 110 mA
230VAC @ 57 mA

Dimensions

8.25 In. [209.55 mm] x 8.25 In. [209.55 mm] x 4.25 In.
[107.95 mm] Box (add 0.625 In. [15.88 mm] top and
bottom for mounting Flange).

6.50 In. [165.10 mm] x 5.00 In. [127.00 mm] x 3.29 In.
[83.57 mm] panel mounted printed circuit board.
Requires 3.03 In. [76.96 mm] of panel depth.

Inputs

Inductive proximity sensors: npn, open collector,
current sinking, or NAMUR.

Inductive proximity sensors: npn, open collector,
current sinking, or NAMUR.

Outputs

Relay: 28VDC, 115/230VAC @ 2 Amps. K1:
+12VDC @ .6 Amps power available, used to operate
clutch solenoid. K2: available
for auxiliary use. No power available.

Relay: 28VDC, 115/230VAC @ 2 Amps.
K1: +12VDC @ .6 Amps power available, used to
operate clutch solenoid. K2:
available for auxiliary use. No power available.