REPLACEMENT PROCEDURE–MALE PILOT BEARINGS

FIGURE 13

WARNING

Always wear safety goggles when working

with spring or tension loaded fasteners

or devices, such as the Retaining Rings.

Refer to Figure 13

1. Remove the Retaining Ring (Item 32) from the Stub

Shaft (Item 31).

2. Press the Stub Shaft (Item 31) out of the Male Pilot

(Item 27).

3. Remove the Retaining Ring (Item 28) from the Male

Pilot (Item 27) and press the old Bearings (Item 29) out
of the Male Pilot (Item 27).

4. Clean the bearing bore of the Male Pilot (Item 27) with

fresh safety solvent, making sure all old Loctite

®

residue

is removed.

5. Apply an adequate amount of Loctite

®

680 to evenly

coat the outer race of new Bearings (Item 29).

6. Carefully align the outer race of the new Bearings (Item

29) with the bore of the Male Pilot (Item 27).

7. Press the new Bearings (Item 29) into the Male Pilot

(Item 27).

8. Reinstall the Retaining Rings (Item 28 and 32).

9. Apply a thin film of NEVER-SEEZ

®

to evenly coat the

spline of the Stub Shaft (Item 31).

10. Slide the Male Pilot (Item 27) and the Stub Shaft (Item

31) into the Air Chamber (Item 14), aligning the Spring
Pin (Item 25) in the Male Pilot (Item 27) with a hole in
the Piston (Item 17). (See Figures 10 & 11)

11. Apply a drop of Loctite

®

242 to the threads of the

Socket Head Cap Screws (Item 8).

12. Reinstall the four Socket Head Cap Screws (Item 8)

securing the Male Pilot (Item 27) to the Air Chamber
(Item 14).

13. Tighten the four Socket Head Cap Screws to 509 in-lbs

(57.5 N-m).