Installation (continued...) – Nexen 1625 Input Unit 936001 User Manual

Page 5

Advertising
background image



21070-D-0707

INSTALLATION (continued...)

NOTE: Refer to Figures 1 and 3.

NOTE: Use Loctite® 242 on all Socket Head Cap Screws.

1. Remove the four Socket Head Cap Screws (Item 8) and

separate the Female Pilot (Item 1) from the Housing
(Item 7).

2. Place Key (Item 19) into the keyway of the Input Unit.

3. Slide the Female Pilot (Item 1) onto the Input Unit.

Secure the Input Unit and the Mounting Foot to the
Female Pilot (Item 1) using four Socket Head Cap
Screws (Items 39 and 40). Tighten the Socket Head
Cap Screws to 1425 in-lbs (161 N-m).

4. Tighten the Set Screw (Item 35) to 275 in-lbs (31 N-m).

5. Secure the second Mounting Foot (Item 38) to the

FMCB Assembly.

6. Secure the Female Pilot (Item 1) assembly to the

FMCB Assembly (Item 7) with the Socket Head Cap
Screws (Item 8). Tighten to 509-662 in-lbs (57.5-74.8

FIGURE 3

39

19

40

INPUT

UNIT

19

35

FEMALE PILOT

ASSEMBLY

33

40

MOUNTING FOOT

(ITEM 28)

FMCB

ASSEMBLY

MOUNTING FOOT

(ITEM 38)

SECTION C: OPTIONAL INPUT UNIT AND FEET

Advertising