OPERATION

AUTOMATIC/MANUAL MODE SELECTION

When the AUTO key is depressed the RSTC will go into
automatic mode; the RSTC Status display will change to
“Auto” to confirm that the RSTC is in automatic mode. At
this stage, the web’s tension is set by the Tension Adjust
knob and maintained automatically.

When the MANUAL key is depressed the RSTC will go
into manual mode; the RSTC Status display will change
to “Man” to confirm that the RSTC is in manual mode. At
this stage, the Tension Adjust knob is used to manually
change the RSTC’s control output level.

Web Tension/Output Level Adjustment And Indication

AUTOMATIC MODE

When the RSTC is in automatic mode (status display
indicates “Auto”) the tension setpoint is adjusted by
turning the Tension Adjust knob. Turning the knob
clockwise will increase the setpoint and turning the knob
counterclockwise will decrease the tension setpoint.
Turning the knob will cause the ROP display to change
from the RSTC Status screen to the Job Setup screen (See
Figure 8). Continue turning the knob until Web Tension
Setpoint is set to the desired tension value. If the knob
is left stationary, the ROP display will return to the RSTC
Status screen after a short delay.

Web tension is indicated by the TENSION display (See
Figure 7). The bar graph display indicates web tension
magnitude as a percentage of the RSTC’s maximum
tension setpoint value entered during RSTC setup.

Job: 03 Job Loaded

Delay: 5.0 in

Taper: 12

Tension SP: 234 lb

Web Tension

Setpoint

Job Loaded/Job

Saved Message

Taper Tension

Delay

Taper Tension

Setpoint

Job Selection

Figure 8

Job Setup Screen

TENSION

+

+

RSTC Status/Job

Setup Display

Communication
Error Indicator

Communication
Indicator

Load Job

Save Job

Job Selection
Taper Delay Adjust

Taper Adjust

Alarm

Acknowledge

Tension
Adjust

Load Cell
Selection

Control Output

ON/OFF

Automatic

Mode

Manual Mode

Figure 6

Figure 7

RSTC Status Screen

Tension: 82.7 lb

Output: 21% Dia: 32.5

Status: Auto Stop

RSTC

Status

Auto/Man

Stop/Run

Roll

Diameter

Alarm

Message

Tension/Output

Level Bar Graph

Web Tension

Control Output

Level

Advertising