3. Using cables provided with the sensors, make the

connections for either left hand or right hand EPC, or

CPC (See Figure 6).

4. Connect AC Power in the range of 100 to 240VAC

to Terminals  and 2. Connect Terminal  to ground

(See Figure 6).

5. Connect motor output lead to Terminals  and .

Connect cable shield to Terminal  (See Figure 6).

6. Connect optional Travel Limit Switches to Terminals

, 7, and 8 (See Figure 6).

NOTE: If Limit Switches are not used, short all three

terminals together.

7. Connect Automatic Centering Sensor (Product No.

912696) to Terminals 9 and 0 (See Figure 6).

8. Connect the optional Lock Out Switch to Terminals

9 and 20 (See Figure 6).

NOTE: The Lock Out Switch is a customer supplied

switch rated at 15VDC, 250mA, N.O.,

momentary contact.

9. If used, connect optional RP10 Remote Controller

(Product No. 912695) to Terminals 2-2 (See

Figure 6).

10. If used, connect a customer supplied Remote Fine

Adjustment Pot, rated 10K ohm, to Terminals 2, 22,

0, and  (See Figure 6).

FIGURE 