Altera MAX 10 Embedded Multipliers User Manual

Page 20

Advertising
background image

GUI Parameter

Parameter

Condition

Value

Description

What is the source for

clock input?

INPUT_REG_B • Input

Configuration

> Register

input B of the

multiplier =

On

• Input

Configuration

> More

Options

Clock0–Clock3

Specifies the clock port

for the

datab[]

port.

What is the source for

asynchronous clear

input?

INPUT_ACLR_

B

• Input

Configuration

> Register

input B of the

multiplier =

On

• Input

Configuration

> More

Options

• Aclr0–Aclr2

• None

Specifies the asynchro‐

nous clear port for the

datab[]

port.

What is the input A of

the multiplier

connected to?

—

—

Multiplier input By default, input A of

the multiplier is always

connected to the

multiplier’s input.

What is the input B of

the multiplier

connected to?

—

—

Multiplier input By default, input B of

the multiplier is always

connected to the

multiplier’s input.

Register output of the

multiplier

—

—

On or Off

Turn on to enable

register output of the

multiplier.

What is the source for

clock input?

MULTIPLIER_

REG

• Output

Configuration

> Register

output of the

multiplier =

On

• Output

Configuration

> More

Options

Clock0–Clock3

Specifies the clock

signal for the register

that immediately

follows the multiplier.

UG-M10DSP

2014.09.22

ALTMULT_ACCUM Parameter Settings

5-5

ALTMULT_ACCUM (Multiply-Accumulate) IP Core References