Altera Reed-Solomon Compiler User Manual
Page 29
Advertising
Chapter 3: Functional Description
3–11
Throughput Calculator
December 2014
Altera Corporation
Reed-Solomon Compiler
User Guide
shows the value of N
C
.
Table 3–9. Calculate N
C
Erasures
Keysize
N
C
No
Half
Max (N, 10 × R + 4)
No
Full
Max (N, 7 × R + 5)
Yes
Half
Max (N, 10 × R + 6)
Yes
Full
Max (N, 8 × R + 4)
Advertising