Venting installation – Desa WCM-36J User Manual

Page 8

Advertising
background image

www.desatech.com

122271-01B

8

Figure 9 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

Georgian

Fireplace

66

1

/

2

"

12-12DM

12-12HT

Pipe Section

10

5

/

8

"

18-12DM

18-12HT

Pipe Section

16

5

/

8

"

24-12DM

24-12HT

Pipe Section

23

5

/

8

"

36-12DM

36-12HT

Pipe Section

34

5

/

8

"

48-12DM

48-12HT

Pipe Section

46

5

/

8

"

RLT-12D

RLT-12HT

Round Termination

7

3

/

4

"*

STL-12D

Square Chase-Top

with Slip Section

7" to 15"*

* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.

Hemmed
End

12

3

/

8

"

Stainless
Inner Pipe

15" Galvanized
Outer Pipe

ASSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of a
galvanized outer pipe, a stainless steel inner flue
pipe and a wire spacer. The pipe sections must
be assembled independently as the chimney is
installed. When connecting chimney directly to
the fireplace, the inner flue pipe section must
be installed first with the lanced side up. The
outer pipe section can then be installed over
5 the flue pipe section with the hemmed end
up. Press down on each pipe section until the
lances securely engage the hem on the fireplace
starter. The wire will assure the proper spacing
between the inner and outer pipe sections.

Figure 8 - Outside Air Kit

Secure to Collars with Metal Tape,
Screws or Straps (Min. of 1/4" x 20"
in size)

Air Inlet
Location
Must Allow
For Bushes
or Snow

Vent Hood
Required for
Wall Installation

Air Inlet
Eyebrow

Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)

CHIMNEY PIPE

The DESA Heating, LLC chimney system
consists of 12", 18", 24", 36" and 48" snap-
lock, double-wall pipe segments, planned
for maximum adaptability to individual site
requirements. Actual lengths gained after
fitting overlaps must be taken into consider-
ation (lineal gain) and are given in the lineal
gain chart (see Figure 9). Lineal Gain is the
actual measurable length of a part after two or
more parts are connected. For Canada, use
chimney parts designated "HT".

VenTing inSTallaTion

OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)

The installation of an outside air kit should
be performed during the rough framing of
the fireplace due to the nature of it's location.
Outside combustion air is accessed through
a vented crawl space (AK4F) or through a
sidewall (AK4).

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

The maximum height for the

air vent can not exceed 3 feet

below the flue gas outlet of the

termination.

WARNING: The opening in

the collar around the chimney at

the top of the fireplace must not

be obstructed. Never use blown

insulation to fill the chimney

enclosure.