Gas line hook up should be done by your
supplier or a qualified service person.
Note: Before you proceed, make sure your
gas supply is turned off.
Use only a 1/2" black iron pipe and appropri-
ate fittings.
1. Remove knockout indentation on refrac-

tory or firebrick wall located above refrac-
tory hearth floor. Knockout indentation
must be firmly tapped with any solid object
such as a 1/2" dowel until it is released.
Remove fragmented portions of refractory
(see Figure 21).

2. Remove gas line cover plate located on

either side of fireplace and pull out insula-
tion from gas line conduit sleeve. Save
insulation for reuse. Replace screws.

3. Run a 1/2" black iron gas line into fireplace

through the rear at gas line conduit sleeve (if
using a raised platform, add height). Provide
sufficient gas line into fireplace chamber for
fitting connection (see Figure 22).

Note: Secure incoming gas line to wood
framing to provide rigidity for threaded end.

4. Repack insulation around gas line and into

sleeve opening. Seal any gaps between
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement, Install the gas appliance or cap-off
gas line if desired.

CAUTION: All gas piping

and connections must be tested

for leaks after the installation

is completed. After ensuring

that the gas valve is on, apply

soap and water solution to all

connections and joints. Bubbles

forming show a leak. Correct

all leaks at once. DO NOT USE

AN OPEN FLAME FOR LEAK

TESTING AND DO NOT OPER-

ATE ANY APPLIANCE IF A LEAK

IS DETECTED. LEAK TESTING

SHOULD BE DONE BY A QUALI-

FIED SERvICE PERSON.

WARNING: Do not operate an

unvented gas log set in this fire-

place with the chimney removed.

Figure 21 - Gas Line Access

Side
Firebrick
Finished
Side

Brick with
Access
Hole

Outside of
Fireplace

Gas Line
Conduit

Insulation

Gas
Conduit
Cover

1/2" Dowel

Seal
Opening
with
Refractory
Cement

Outside of
Fireplace

Gas Line
Conduit

Repack
Insulation

Incoming
1/2" Black
Iron Pipe

Side
Firebrick
Finished
Side

Provide Enough
Threaded
End for Fitting
Connection

Figure 22 - Gas Line Installation

Remove
Knockout

opTional gaS line inSTallaTion

If you install a decorative gas appliance
(vented gas log), the decorative gas appliance
must comply with the Standard for Decorative
Gas Appliance for Installation in Solid Fuel
Burning Fireplaces, ANS Z21.60, Z21.84 or
RG 2-72
and shall also be installed in accor-
dance with the National Fuel Gas Code, ANSI
7223NFPA 54 latest edition
.

WARNING: If the fireplace

has been used for wood burning,

the firebox and chimney must be

cleaned of soot, creosote and

ashes be a qualified chimney

cleaner. Creosote will ignite if

heavily heated.

WARNING: When using a

decorative vented gas log, the

damper must be removed or per-

manently locked in the fully open

position and the glass doors must

be in the fully open position.

Advertising
This manual is related to the following products: