Figure 33 - Bi-Fold Glass Doors

Doors Fully Closed

Fireplace Front

Doors

Fully Opened

Fireplace Front

operaTion and MainTenance guidelineS

GLASS DOORS

Glass doors are optional with the fireplace.
When fireplace is in operation, doors must be
fully opened or fully closed position only or a
fire hazard may be created (see Figure 33).
A fireplace equipped with glass doors oper-
ates much differently than a fireplace with an
open front. A fireplace with glass doors has a
limited amount of air for combustion.
Excessive heat within the fireplace can result
if too large a fire is built or if combustion air
gate is not completely open. The following
tips should be followed to assure that both
the fireplace and glass door retain their beauty
and function properly. Both the flue damper
and glass doors must be fully opened before
starting fire. This will provide sufficient com-
bustion air and maintain safe temperatures
in firebox.
IMPORTANT: The glass must be allowed to
warm slowly and evenly. The tempered glass
will withstand a gradual temperature rise to
550° F, which is more than a normal fire will
generate. Such materials as pitch/wax laden
logs, very dry mill end lumber and large
amounts of paper or cardboard boxes can
create an excessively hot fire and should not
be burned in this fireplace. Always keep the
fire well back from the doors and never allow
flames to contact the glass.

WARNING: Fireplaces

equipped with glass doors

should be operated only with

doors fully opened or doors fully

closed. Doors, if left partly open,

may draw gas and flame out of

the fireplace opening creating

risks of both fire and smoke.

Cleaning Glass
Clean glass with any commercial glass
cleaner or soap and water. Do not use any
abrasive material to clean glass. Do not clean
glass with any cool water if glass is still hot
from the fire and smoke.
A gas line or gas log lighter may be installed
for the purpose of installing a vented or vent-
free decorative gas appliance incorporating an
automatic shutoff device and complying with
the Standard for Decorative Gas Appliances
for Installation in Vented Fireplaces, ANSI
Z21.60
or American Gas Association draft
requirements for Gas Fired Log Lighters for
Wood Burning Fireplaces, Draft NO. 4
dated
August, 1993.
If you wish to install an unvented (vent-free)
gas log set, only unvented gas log sets which
have been found to comply with the standard
for unvented room heaters, ANSI Z21.11.2 are
to be installed in this fireplace.