Figure 9 wiring diagram – Ducane (HVAC) (2/4)SH13 User Manual

Page 11

Advertising
background image

# 48369K005

Page 11

Figure 9

Wiring Diagram

P/N 48349-001

208/230V

-1-60

G

W1

CR

O

BLK

RED

YEL

RED

CONT

A

C

T

O

R

THERMOST

A

T

HIGH PRESSURE

SWITCH

(IF USED)

L1

T1

T2

L2

C

H

F

CONDENSER

F

AN MO

T

O

R

COMPRESSOR

CONT

A

C

T

O

R

COMPRESSOR

CONT

A

C

T

O

R

DU

AL

CAP

A

CIT

OR

COMPRESSOR

TRANSFORMER

C

S

R

WHT

L2

L1

BLK

BRN

PUR

RED

RED

BLK

208V

240V

24V

INDOOR

BLO

WER

M

OTO

R

NO

TE:

IF ANY OF

THE ORIGINAL

WIRE IS REPLA

CED

THE

SAME SIZE AND

TYPE

WIRE

MUST BE USED

.

USE

COPPER CONDUCT

OR ONL

Y

,

MIN 75°C

WIRE.

LINE

V

O

LT

A

GE FIELD INST

ALLED

.

W

ARNING-

ELECTRIC SHOCK HAZARD

.

UNIT

MUST BE GR

OUNDED

IN A

CCORD

ANCE

WITH

NA

TIONAL AND LOCAL CODES

.

S4

S1

K1

T1

B3

B4

K1-2

C12

B1

K1-1

BLU

YEL

C4

CAP

A

CIT

OR

H

M

L

C

SEE CHAR

T

FOR

WIRING

M

OTO

R

SPEED

T

APS

NO

NC

C

P-3

BLO

WER

CONTR

OL

A15

NC

C

CMC1

BLK

C

G

XFMR-R

R

XFMR-C

W1

C

L

R

O

Y1

FA

N

O-OUT

LO-PS

DF

HI-PS

COMMON

Y1 OUT

2

2

CMC1

S6

L1

24

V

FUSE

Y

A15

BLO

WER

CONTR

OL

W2

RED

YEL

BLU

WHT

GRN

ORN

RED

BLU

BLU

YEL

BLU

DIAGNOSTIC DISPLA

Y

Note:

Because the pressure s

witches are monitored only when "Y1" (Input) is activ

e

, the code f

o

r

pressure s

witch open will not be seen when "Y1" is off

.

Instead, the

“Nor

mal Oper

ation" or

“Anti-Shor

t Cycle Loc

k

out”

code will be seen.

When a pressure s

witch opens and causes a shor

t cycle loc

k

out, the

pressure

s

witch-open code will be seen until it closes

, then the shor

t cycle loc

k

out code

will flash unless it has already e

xpired.

W1 &

W2 CAN BE USED

T

O

ST

A

G

E

ELECTRIC HEA

T

A

CCESSOR

Y ON 15 & 20KW MODELS

.

5, 7.5,

& 10KW HEA

TER A

CCESSORIES FUNCTION

OFF

W1 ONL

Y

.

BLK

BLK

DEFR

OST

CONTR

OL

BLU

WHT

REVERSING

VA

LV

E

DEFR

OST

T'ST

A

T

DEFR

OST CONTR

OL

P-1

P-2

P-4

P-6

P-5

CONNECTION MUST BE JUMPERED

WHEN PRESSURE SWITCH IS NO

T USED

.

2

Unit

F

a

c

tor

y

S

hipped

Se

tt

in

g

s

C

ooling

Input

(B

L

K

)

24

LO

W

30

MED

36

HIGH

42

LO

W

48

MED

60

HIGH

Mode

G

reen

LE

D

(D

S

2

)

Re

d

L

ED

(D

S1

)

No

P

o

w

e

r

to

Board

O

ff

Off

Nor

m

al

Oper

ation/

P

o

w

e

r

to

Board

Sim

u

ltaneous

Slo

w

Flash

Anti-Shor

t

C

ycle

Loc

k

out

Alter

nating

S

lo

w

F

lash

Lo

w

P

ressure

Switch

F

ault

Off

Slo

w

Flash

Lo

w

P

ressure

Switch

Loc

k

out

Off

O

n

High

Pressure

Switch

F

ault

Slo

w

Flash

Off

High

Pressure

Switch

Loc

k

out

On

Off

L

M

HC

BLOWER SPEED CHAR

T