Delta Electronics AC Motor Drive VFD-E User Manual
Page 172

Chapter 4 Parameters|
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
4-119
Function 08H
Function 08H
00H
00H
Data address
00H
Data address
00H
17H
17H
Data content
70H
Data content
70H
CRC CHK Low
EEH
CRC CHK Low
EEH
CRC CHK High
1FH
CRC CHK High
1FH
(3) 08H: loop detection
This command is used to detect if the communication between master device (PC or PLC)
and AC motor drive is normal. The AC motor drive will send the received message to the
master device.
ASCII mode:
Command message:
Response message:
STX ‘:’
STX ‘:’
‘0’
‘0’
Address
‘1’
Address
‘1’
‘0’
‘0’
Function
‘8’
Function
‘8’
‘0’
‘0’
‘0’
‘0’
‘0’
‘0’
Data address
‘0’
Data address
‘0’
‘1’
‘1’
‘7’
‘7’
‘7’
‘7’
Data content
‘0’
Data content
‘0’
‘7’
‘7’
LRC Check
‘0’
LRC Check
‘0’
CR
CR
END
LF
END
LF