Venting installation instructions – Desa CGCDV36NR User Manual

Page 15

Advertising
background image

15

15

www.desatech.com

116200-01C

VENTING INSTALLATION

INSTRUCTIONS

Continued

Vertical Venting

V = 40' max.

Figure 24 - Vertical Venting Configuration With No Horizontal

Run (Vertical Round High Wind Termination Shown)

Note: Install restrictor

into inner collar of

fireplace as shown.

45° Elbow

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and approved for

elevations from 0-2000 feet (USA) and elevations from 0-4500

feet (Canada) .
When installing this fireplace at an elevation above 2000 feet (in

the USA), you may need to decrease the input rating by changing

the existing burner orifice to a smaller size. Reduce input 4% for

each 1000 feet above sea level. Check with your local gas company

for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in

Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice

for your location.
For assistance with any high altitude installation contact DESAʼs

Customer Service Department at 1-866-672-6040.

VENTING INSTALLATION INSTRUCTIONS

Installation for Vertical Termination (Cont.)

High Altitude Installation

Advertising
This manual is related to the following products: