INSTALLATION

WARNING: Before installing in a solid fuel burning

fi replace, the chimney fl ue and fi rebox must be cleaned
of soot, creosote, ashes and loose paint by a qualifi ed
chimney cleaner. Creosote will ignite if highly heated.
A dirty chimney fl ue may create and distribute soot
within the house. Inspect chimney fl ue for damage. If
damaged, repair fl ue before operating heater.

NOTICE: Installation, service, and repair of this appli-
ance must be performed by a qualifi ed installer, service
agency, company or gas supplier experienced with
this type of gas appliance. Only factory authorized
components listed in these instructions may be used
in accordance with the manufacturer’s instructions
and all codes and requirements of the authority hav-
ing jurisdiction. Any modifi cations to this kit, or use
of unauthorized components or accessory items will
void the manufacturer’s warranty, and may result in
a hazardous condition.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you
MUST NOT install this gas log set

If the fi replace does not have a gas supply shutoff valve, one must
be installed.

CAUTION: Do not remove the data plates attached

to the burner pan. The data plates contain important
warranty information.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only in a solid-fuel
burning fi replace with a working fl ue and constructed of noncom-
bustible material.

The charts in Figure 2 indicate technical information regarding
the installation of your gas log set. Please make sure that all of
the specifi cations shown are applicable before installation is at-
tempted.

The fi replace must include a working fl ue and venting system with

VENTING SPECIFICATIONS FOR
INSTALLATION

The fi replace chimney fl ue and vent must be drafting properly. To
check the vent for proper drafting: Light a tightly rolled newspaper
on one end and place it at the inside front edge of the fi replace. Ob-
serve the smoke and be sure the vent is properly drawing it up the
chimney. If the smoke spills out into the room, extinguish the fl ame
and remove any obstruction until proper venting is achieved.

The chimney fl ue must remain open a minimum of 3" at all times
during the operation of this log set.

Figure 2 - Technical Information Charts

INSTALLATION

Flue Opening Specifi cations
Check Gas Type
Venting Specifi cations for Installation

Model

Burner

Description

BTU Input

(Natural Gas)

Minimum Vent

Opening

PHK/ BCS 18

18" Ramp

57,000

8"

PHK/ BCS 24

24" Ramp

80,000

8"

PHK/ BCS 30

30" Ramp

90,000

8"

Minimum Fireplace Dimensions

Model

Front

Width

Back

Width*

Depth

Height

PHK/ BCS 18

28"

18"

16"

18"

PHK/ BCS 24

36"

23"

16"

18"

PHK/ BCS 30

42"

29"

18"

18"

* At depth Indicated

Fuel Inlet Pressure

Specifi cations (W.C.)

Min.

Max.

N.G.

5.5"

10.5"

Burner Orifi ce Sizing

Log Size

Natural Gas

In.

Num.

18"

.120

31

24"

.140

28

30"

.1495

25