Operating heater – Desa CGN18R User Manual

Page 18

Advertising
background image

18

099434

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including

near the floor. If you smell gas, STOP! Follow “B” in the safety information
at the top of page 17. If you don’t smell gas, go to the next step.

5. Press in control knob.

Note:

You may be running this heater for the first time after hooking up

to gas supply. If so, you may need to press in control knob for 30 seconds.
This will allow air to bleed from the gas system.

• If control knob does not pop up when released, contact a qualified

service person or gas supplier for repairs.

6. Keep control knob pressed in and turn it counterclockwise

C-clockwise

to the

PILOT/IGN position. This will light pilot.

Note:

You will hear a loud “click” when the control knob reaches the

PILOT/IGN position.

If pilot does not light

• turn control knob clockwise

Clockwise

to the OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

• refer to Troubleshooting, pages 22 through 25
• contact a qualified service person or gas supplier for repairs

Until repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure
, page 20.

7. Keep control knob pressed in for 10 seconds after lighting pilot. After 10

seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7.

Ignitor Electrode

Figure 16 - Pilot

Pilot Burner

Thermocouple

OPERATING

HEATER

Continued