Step 4 - selecting current

920-0031 A

Step 3 - selecting the motor

Selecting the motor
Motor selection is done with the 16 position

rotary switch on the front of the drive; refer to

the label on the drive to see the motor choices

available to you. Turn the rotary switch to the

number that represents the motor you have.

This selects important information stored on

the drive, such as current and anti-resonance

settings, to get the best performance from

your motor.

Setting up the Drive

Sets the running current to

70%, 80%, 90% or 100% of the

motor’s rated maximum current.

1 2

100%

1 2

90%

1 2

80%

1 2

70%

SW3 chooses between two load

inertia ratio ranges.

This information is used in the anti-

resonance configuration.

3

5-10X

3

0-4X

There are 4 microstep resolutions to

choose from as well as full and half step.

▪ 200
▪ 200 with microstep emulation (smooth)
▪ 400
▪ 400 with microstep emulation (smooth)
▪ 2000
▪ 5000
▪ 12800
▪ 20000

5 6 7

20000

5 6 7

12800

5 6 7

5000

5 6 7

2000

5 6 7

400

SMOOTH

5 6 7

400

5 6 7

200

SMOOTH

5 6 7

200

A full user manual for the STR is available for download

from our web site. This contains full details on setup,

wiring and installation.
www.applied-motion.com/support

Step 5 - load inertia

Step 6 - step resolution

Step 7 - self test

4

50%

4

90%

SW4 sets the idle

current to either

50% or 90% of the

selected running

current.

The STR has a built in Self Test function. If switch 8 is

moved to the ON position the drive will automatically rotate

the motor back and forth, two turns in each direction. This

feature can be used to confirm that the motor is correctly

wired, selected and otherwise operational.

8

ON

8

OFF

SELF TEST

Step 8 - user manual