UNVENTED NATURAL GAS FIREPLACE

LFP33NR

SPECIFICATIONS

LFP33NR Remote Ready

Btu (Variable)

20,000/30,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at 1-800-DESA LOG
(1-800-337-2564).

You can also visit DESA International’s
Technical Service web site at

www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

When Gas Quality Is Bad

• pilot will not stay lit

• burners will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.

AUT

O

OFF

ON

Thermopile

WIRING DIAGRAM

Note

: For proper operation of optional ac-

cessories, the wires from the switch to the
control must be connected exactly as shown.