Checking gas connections, Connecting to gas supply, Warning – Desa CGP26D User Manual

Page 15: Caution

Advertising
background image

15

101827

IMPORTANT:

Hold pressure regulator with wrench when connecting it to gas piping

and/or fittings.

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Test

Gauge

Connection *

Tee Joint

Pipe

Nipple

Cap

Manual
Shutoff
Valve *

1/2" NPT
Pipe Nipple

Heater
Cabinet

Pressure
Regulator

Figure 13 - Gas Connection

3" Minimum

Ground Joint
Union

From

External Regulator

(11" W.C. to 14" W.C. Pressure)

CHECKING

GAS

CONNECTIONS

WARNING

Test all gas piping and connections for leaks after installing or
servicing. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply

piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.

Sediment

Trap

CONNECTING

TO GAS

SUPPLY

Continued

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessories, page 27.

WARNING

Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.

CAUTION

Make sure external regulator has been installed between propane/
LP supply and heater. See guidelines under

Connecting to Gas

Supply, page 14.

Continued

Advertising