6 precision barometer, Standard sensors, 1 precision barometer specification – Casella CEL Automatic weather station User Manual
Page 24

3.5.2
Standard Barometer - Sensus Channel Configuration
Description
Pressure
Units
mbar
Type
Analog
Information
Single ended
Gain x 1
No current source
Display Format
####.#
Polynomial
Sensor specific
Enabled
Yes
Logged
Yes
Minimum Limit
800.0
Maximum Limit
1100.0
3.6
Precision Barometer
A precision barometer may be supplied.
3.6.1
Precision Barometer Specification
Part number:
P120640B
Transducer:
The pressure sensor is temperature stabilised
at 60
o
C
Range:
900 to 1100 hPa (mB)
Operating temp:
-20°C to + 50°C
Accuracy:
±0.3 hPa (mB) over 35
o
C range
Hysteresis:
±0.1 hPa (mB)
Linearity:
±0.1 hPa (mB)
Supply voltage:
9 - 12 V nominal
Power consumption:
Approx. 60 mA at 12 V
3.6.2
Precision Barometer - Sensus Channel Configuration
Description
Pressure
Units
mbar
Type
Analog
Standard Sensors
Precision Barometer
Page 24 of 34
Automatic Weather Station
Assembly & Commissioning Handbook