Nstallation, Nstructions, Warnings – Dacor MCS130 User Manual

Page 10: Warning, Ounting

Advertising
background image

8

i

nsTallaTion

i

nsTRuCTions

Conduit from

appliance

Cable from

power supply

Wire nut

(4 places)

Junction

box

RED

RED

GREEN

GREEN

WHITE

WHITE

BLACK

BLACK

Separate No. 10 (minimum)

copper grounding wire

Clamp must be

tight on pipe

No. 4

copper wire

Metal

water pipe

Clamps

Bare metal

Meter

Connecting the Appliance Ground to a Grounded Junction Box Wire or Cold Water Pipe.

WARNINGS

1. Do not ground the appliance to a gas supply pipe or hot

water pipe.

2. Do not turn on power to the appliance until the oven is

permanently grounded.

3. Grounded cold water pipe must have metal continuity

to electrically ground and must not be interrupted by

insulating materials. Any insulating materials must be

jumped as shown below with a length of No. 4 copper

wire securely clamped to bare metal at both ends.

Lift the wall oven up to the cabinet cutout, using the upper edge of the

cavity opening and the bottom of the oven case side as gripping points.

Use extreme caution when lifting the appliance as it is heavy. Be certain to

take all necessary safety precautions.

Resting the oven on the cabinet-mounting platform, slide the oven into

the recessed area until the rear edge of the oven frame is flush with the

cabinet face and the oven is centered within the cutout. Ensure that the

electrical conduit slides through the opening in the cabinet platform or

coils above the oven chassis as the oven is slid into place. The cable

must be placed into the recessed area located along the rear vertical edge

of the oven or coiled above the oven chassis. Do not trap the appliance

cable between the oven case back and the rear wall.

WARNING

1. Failure to install the mounting screws may result

in movement or tipping of the oven during use and

personal injury.

2. Do not block the oven air exhaust located at the bottom

of the oven. Blocking the intake may cause cabinet

damage and poor baking performance.

m

ounTing

The

o

ven

Oven Gripping Points

C. Connecting the Green Appliance Wire to a

Grounded Junction Box Wire or Grounded Cold

Water Pipe – Where Local Codes Permit

1. Separate the green and white appliance wires.

2. Connect the black appliance wire to the black (L1) power supply wire

in the junction box.

3. Connect the red appliance wire to the black (L2) power supply wire in

the junction box.

4. Connect the red appliance wire to the red (L2) power supply wire in

the junction box

5. Connect the green appliance wire to a grounded wire in the junction

box or to a grounded cold water pipe.

6. If connecting to a grounded cold water pipe, a separate copper

grounding wire (No. 10 minimum) must be connected to a grounded

cold water pipe by means of a clamp and then to an external

grounding connector screw.

For the single ovens and the upper cavity of the double ovens, locate the

mounting holes found in the sides of the oven frame. Using a 1/16” drill,

drill four pilot holes for the #6 x 3/4” screws provided in the instruction

envelope. Install the screws through the oven frame and into the cabinet

to secure the oven. Do not over-tighten the screws.

Repeat the mounting procedure for the lower cavity if installing a double

oven.

Advertising