Nstallation, Nstructions – Dacor MCS130 User Manual

Page 9

Advertising
background image

7

Before attempting to connect the appliance to power, turn off the

electrical power supply. Also, always turn off electrical power to

the appliance prior to servicing it.

The appliance must be connected to the power supply with copper

wire only. The use of aluminum wire may result in unsatisfactory

connections. Flexible armored or non-metallic, sheathed copper

cable (with grounding wire) should be used to connect the

appliance to the junction box. A UL-listed connector must be used

to directly connect the cable to the junction box.

Be certain to locate the junction box such that the electrical supply

may be easily disconnected in the event that service becomes

necessary. Also, provide extra slack in the cable to allow the oven

to slide forward for servicing.

This appliance must be electrically grounded.

With the oven positioned directly in front of the cabinet cutout,

feed the appliance conduit to the electrical junction box.

Then, depending upon local codes, utilize one of the following

techniques to connect the appliance to the electrical power

supply:

T

uRning

o

ff

The

p

oweR

s

upply

e

leCTRiCal

C

onneCTion

WARNING

WARNING – Failure to disconnect power may result in

electrical shock or fire hazard.

WARNING

1. This appliance must be connected to a grounded,

metallic, permanent wiring system. Alternatively, a

grounding conductor should be connected to the

grounding terminal or lead on the appliance. Failure to

do so may result in an electrical shock hazard.

2. Do not install a fuse in the neutral or ground circuit. A

fuse in the neutral or ground circuit may result in an

electrical shock hazard.

g

Rounding

i

nsTRuCTions

i

nsTallaTion

i

nsTRuCTions

A. Connecting to a Four-Wire Electrical System

1. Separate the green and white appliance wires.

2. Connect the white appliance wire to the neutral (white) supply wire in

the junction box.

3. Connect the black appliance wire to the black (L1) power supply wire

in the junction box.

4. Connect the red appliance wire to the red (L2) power supply wire in

the junction box.

5. Connect the green appliance wire to the green house grounding wire

Conduit from

appliance

Cable from

power supply

Wire nut

(4 places)

Junction

box

RED
RED

GREEN
GREEN

WHITE
WHITE

BLACK
BLACK

Connecting the Appliance to a Four-Wire Power Supply

WARNING

WARNING – Do not connect the green appliance wire to

the neutral (white) junction box wire unless local building

codes permit.

Conduit from

appliance

Cable from

power supply

Wire nut

(3 places)

Junction

box

RED
RED

GREEN

WHITE

WHITE

BLACK
BLACK

Connecting the Appliance Ground to Supply Neutral

B. Connecting the Green Appliance Wire to the Neutral

(White) Supply Wire – Where Local Codes Permit

1. Connect the green and white appliance wires to the neutral (white)

supply wire in the junction box.

2. Connect the black appliance wire to the black (L1) power supply wire

in the junction box.

3. Connect the red appliance wire to the black (L2) power supply wire in

the junction box.

Advertising
This manual is related to the following products: