Venting installation, Continued, Firestop spacers (fs-10) – Desa (V)3612ST User Manual

Page 8

Advertising
background image

www.desatech.com

115603-01C

8

2" (5.1cm)

Minimum

VenTing inSTallaTion

Continued

OFFSET CHART

Figure 17 - Chimney Supports

Straps

OFFSET

RISE

CHIMNEY LENGTH

A

B

48"

36"

18"

12"

4

3

/

8

"

16

3

/

8

"

ELBOW SET ONLY

9

1

/

2

"

25

1

/

4

"

1

12

1

/

2

" 30

3

/

8

"

1

14

3

/

8

"

34"

2

17

5

/

8

" 39

1

/

4

"

1

1

21

1

/

2

"

46"

1

22

3

/

4

" 48

1

/

8

"

1

2

26

3

/

8

" 54

7

/

8

"

1

26

3

/

8

"

60"

1

1

31

3

/

4

" 63

3

/

4

"

1

1

34

3

/

4

"

69"

1

1

38

5

/

8

" 75

5

/

8

"

2

39

7

/

8

" 77

7

/

8

"

1

1

1

43

3

/

4

" 84

1

/

2

"

1

1

46

3

/

4

" 87

3

/

4

"

2

1

48

7

/

8

" 93

3

/

8

"

2

Figure 16 - Rise and Offset

B

A

Screws

2" (5.1cm)

Minimum

Angled Firestop

Ceiling
Support

Return
Elbow

TYPICAL OFFSET INSTALLATIONS

OFFSET

ELBOW

OFFSET

ELBOW

RETURN

ELBOW

OFFSET

ELBOW

RETURN

ELBOW

RETURN

ELBOW

RETURN

ELBOW

CEILING

SUPPORT

PIPE

V12S-8DM

6' MAX

(15.2cm)

6' MAX

(15.2cm)

6' MAX

(15.2cm)

6' MAX

(15.2cm)

6' MAX

(15.2cm)

6' MAX

(15.2cm)

Figure 18 - Typical Offset Installations

FIRESTOP SPACERS (FS-10)

Firestop spacers are required at each point
where the chimney penetrates a floor or ceil-
ing joist space. Their purpose is to establish
and maintain the required clearance between
the chimney and the combustible materials.
When the pipe passes through a framed
opening into a living space above, the firestop
must be placed onto the ceiling from below as
shown in Figure 19, page 9.
They also provide complete separation from
one floor space to another or attic space as
required by most codes. When the double wall
pipe passes through a framed opening into an
attic space, the firestop must be placed into an
attic floor as shown in Figure 20, page 9.
When penetrating a floor or ceiling at an
angle, use firestop spacer number 30 FS-
10D (see Replacement and Accessory Parts,
page 15).

30 FT.

(9.14m)

30 FT.

(9.14m)

Figure 15 - Elbow Offset

Return
Elbow

12S-12DM

Support

Required

Maximum length of pipe between supports
is 6' of angle run. Maximum of two 6' angle
run sections per chimney system (see Figure
9, page 8).