Lsl pf - lift system light push flap – Future Automation LSL-PF User Manual

Page 13

Advertising
background image



In

st

all

at

io

n

: S

ta

ge

8

Page 12 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

LSL PF - Lift System Light Push Flap

You can adjust the IN and OUT position of the lifting beam. Detail 1 shows how
to adjust the OUT position and detail 2 shows how to adjust the IN position.
The IR sensor can be located anywhere outside of the cabinet.

Switch Adjustments

1

2

1 - The top switch can’t be
adjusted when the mechanism
is in the OUT position, because
the switch is active. Lower the
mechanism and press STOP
after about 100mm [4”]. Then
adjust the OUT switch plate by
loosening the bolts and sliding
the plate.

2 - Bottom switch can be adjusted
by repeating the first procedure.

Advertising
This manual is related to the following products: