Lsl pf - lift system light push flap – Future Automation LSL-PF User Manual

Page 15

Advertising
background image

In

st

all

at

io

n

: R

S

23

2 C

on

tro

l

Page 14 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

LSL PF - Lift System Light Push Flap

Connection Locations

Mains Voltage Input

IR LED

IR Input Jack

RS232

Contact Closure























SLQV

RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232

Details
Baud rate: 9600
Stop bit:

1

Parity:

None

Databits:

8

Pin 1: RX

Pin 6 : TX

Pin 3 & 4: GROUND

Pin 2: TX

Pin 3: RX

Pin 5: GROUND

IMPORTANT
Ensure protocol is entered exactly
as written, including Carriage Return
(Enter / ASCII 13).

RJ25

9 PIN D

PIN 1: RX

TO

PIN 2: TX

PIN 6: TX

TO

PIN 3: RX

PIN 3: GROUND

TO

PIN 5: GROUND

PIN 4: GROUND

TO

PIN 5: GROUND

Protocol

Action

fa_in Carriage Return (Enter )

Device IN

fa_out Carriage Return (Enter )

Device OUT

fa_stop Carriage Return (Enter )

Device STOP (At any position)

Emergency Stop Connector

Advertising