Holland Electronics ST-4000 User Manual

Page 5

Advertising
background image

Getting Started

______________________________________________________________________

Powering the Meter

The ST-4000 can be powered either by the internal rechargeable Ni-MH batteries or by use of
the included power supply/battery charger.

A) Using the external AC power supply: Make sure that the available AC line

voltage is 110-120V, 60 Hz. Connect the DC output plug from of the adapter /
charger to the DC receptacle on the bottom of the ST4000 meter.

B) Powering the meter with internal batteries: In order for the ST4000 meter to

operate from the internal batteries, a sufficient charge must exist on the batteries.
The recommended time to fully charge the batteries is 12 hours. Only use the
power supply / battery charger included with the meter. The batteries charge
whether the meter is switched on or off. The Red LED on the meter will illuminate
whenever the power supply / battery charger is attached and plugged into an
110VAC source.


Warning: Use Only The Power Supply / Battery Charger Supplied With The Meter.

Use Of Any Other Will Void Warranty and Can Cause Damage Or Injury.


Quick Use Instructions


To become familiar with the basic operation of the meter it is suggested that the user initially try
the following:

1) Charge the batteries using the supplied power supply/charger unit.
2) Turn the meter on by pressing the On/Off key and check settings in the Set Up menu as

described in Section 1.

3) Check and set the meter to read either CATV or VHF/UHF channels as follows:

i)

From any menu screen Press CLR then Press 2, then Press ENT. The display will
show CH002 if the meter is set for CATV channels or CH02 for VHF/UHF channels.
To switch back and forth between CATV and VHF/UHF channels, perform the
following steps below, otherwise skip to step 4:

ii) Press

the

On/Off key to turn the meter off

iii) Press and hold the SCAN key while pressing the On/Off key
iv) The meter has turned back on and switched between the CATV and VHF/UHF

channels. Repeating steps ii and iii will switch the selected channels again.

4) Carefully align the threads and connect the G-F81 type adapter to the RF Signal input port

on the meter. Hand tighten until the adapter is fully seated. Over tightening the adapter
with a tool can seriously damage the input port on the meter.

5) Connect the CATV or VHF/UHF signal source (cable line, antenna, etc) under test to the

meter.

6) Press “” or “” to scroll through the available channels and note the measured video

signal levels.

7) To switch and display the measured Audio level or V/A differential level values instead of the

Video level, press the 0/2

nd

F key and then press the 3/ V/A key.




3