NE1000 CATV Optical Transmitter Operation and Maintenance Guide

power surges.

4. MONITOR/DATA Port - A 15 Pin D-SUB connector port for monitoring and

controlling the transmitter from a remote status monitoring system. The pin

definitions and functions of the D-SUB connector are shown in Table 1.

5. SELECTION Dip Switches – For setting locally defined functions. See Figure 2

and Table 2 for dip switch functions and settings.

6. RF INPUT – 75

Ω F-type port

7. OPTICAL OUTPUT – An FC/APC port for fiber connection. (As an option the

port can be configured for SC/APC.) Do not look into this port when laser is

operating. The laser can cause serious eye damage.

Pin Function

1 Ground
2

Laser temperature monitor. 1V of output voltage is equivalent to 10

°C.

3

Laser bias current monitor. 1V of output voltage is equivalent to 10 mA.

4

Laser output power status. 1V of output voltage is equivalent to 10 mW.

5

Average RF signal power status

6

Internal power supply voltage monitor. 1V of pin output voltage is equivalent
to 6 volts of power supply voltage. The normal pin voltage is 2V.

7

Status Monitoring (STM) control signal input. The pin is used when
interconnecting a Status Monitoring System.

8

Laser control input. A TTL high input turns the laser off. A TTL low input turns
the laser off.

9

RF gain mode control. A TTL high input sets the transmitter to AGC mode. A
TTL low input sets the transmitter to the MGC mode.

10~15

Not Used

Table 1. Monitor/Data port connector pin functions

6

1 2 3 4 5 6 7 8

DIP

ON

0