KNOX VIDEO
SDI8x8 Routing Switcher

Page 9

[12/00]

SECTION 4. MAINTENANCE

Note: Maintenance of the SDI8x8 should be performed by qualified service

people only.

4.1 INTRODUCTION

The SDI8x8 does not require any routine maintenance.

4.2 SWITCH OPTIONS

An 8-position switch, accessible through the rear panel, is provided for

setting the baud rate and certain programming functions.

Switch positions 1 and 2 are used to set the baud rate for the RS232 control

port. One of four baud rates may be selected as follows:

4.3 SETTING THE ANSWERBACK MODE

The user may choose between two modes of answerback: verbose and non-
verbose. Select the mode using position 3 of the programming switch located on
the rear panel of the SDI8x8. Position 3 ON is verbose, while position 3 OFF is
non-verbose.

In the verbose mode, each time a routing command is sent, the current routing

map will be reported on the RS232 line followed by the word DONE.

In the non-verbose mode only the work DONE will be reported.

In either mode an incorrect or meaningless command will cause the word

ERROR to be reported.

Switch positions 5 through 8 are reserved for programming options not

covered here. Switches 5 through 8 should always be OFF. Switches are ON
when pushed up.

BAUD RATE

19200

1200
2400
9600

SWITCH 1

ON

OFF

ON

OFF

SWITCH 2

ON
ON

OFF
OFF

Advertising