One Systems Natatorium User Manual

Page 21

Advertising
background image

21


The image below shows the rear of the block wall with the

approximate

location of

the rear AL6XN backing plates. The backing plates are shown in red.

Approximate location of 112/NAT rear backing plates on grout filled block wall.


BACKING PLATE LOCATION NOTE: Insure that the backing plates touch a single
block only! Do not allow the backing plates to bridge across to a second CMU block!




All parts except the Boss 801 silicone are available from One Systems.

To mount either a 112/NAT the following parts are required:

2 ea. NASH1009010A 3/8”-16 AL6XN all thread

2 ea. NASH 1009011A Backing plate

4 ea. NASH1009006A Nord-Lock 3-8inSPSS-254 washer sets (each set
consists of two parts bonded together!)

4 ea. NASH1009002A 3/8”-16 AL6XN nuts

1 ea. Boss 801 silicone caulk (contact Boss at 1 800 928 2677 for local distributors
or sources. Call this number for International sources as well.)










Advertising