Synaccess Networks NP-0201DT User Manual

Autoping & power reboot, Power outlet manual switch (if equipped), Snmp and trap (s series)

Advertising
background image

AUTOPING & POWER REBOOT

Each power outlet can be configured to run Autoping

and reboot. Please use the web interface to
complete the settings.

POWER OUTLET MANUAL

SWITCH (IF EQUIPPED)

Press the “Power Outlet Manual Switch” button
located on the front panel. Keep press and release the
button until desired outlet LED is blinking. THEN
HOLD THE SWITCH DOWN FOR 3 SECONDS.
The selected outlet will change the On/Off state.

Note: a user reserved power outlet can’t be manually
controlled.

SNMP AND TRAP (S SERIES)

By default, SNMP agent and TRAP are disabled.
Default community string is “public”. To obtain a
copy of SNMP MIB files, open the device web page.
Down load the MIB file by clicking “get mib file” at
Network Setting” web page.

SAVE/LOAD SETTINGS

Saving and reloading system configuration data file is
done by running a small utility program on a PC. This
operation requires network connection.

Download “synCfg.exe” by visiting
www.synaccess-net.com/support.php

Run the program at DOS prompt: “syncfg.exe –h”

FIRMWARE UPGRADING

The system is firmware upgradable via network.
Please contact us or visit our web site for upgrading
instructions and firmware version information.

PROGRAMMING INTERFACING

The unit can be easily managed by using direct TCP or
serial port interfacing.

Using Telent Port: default port # is 23.
Format: CmdCode Arg1 Arg2

Using HTTP/HTTPS. Note: HTTPS for S version.
http://my_IP_addr/cmd.cgi?cmdCode Arg1 Arg2

Command List

Command

Code

Arg 1

Arg 2

Login

$A1

ID

PWD

Logout

$A2

Set Outlet to
ON/OFF

$A3

Port#

V (1-ON;
0-OFF)

Reboot

$A4

Port#

Get Outlet
Status

$A5

Status Return

$A5

xxxx,cccc,cccc,tt
Or xxxx,cccc,tt

Each “x” denotes an outlet
state (“1” denotes ON; “0”
for OFF). The most right
“x” for relay1. “c” denotes
AC current draw (amp) and
“t” for temperature (c).

Set All Outlet
ON/OFF

$A7

V (1-ON; 0-
OFF)

Return Code

$A0
(OK)

Return Code

$AF
(Failed)

Unknown
Code

$AF

At serial or Telnet terminal, type command
“help” or “?” to get a list of commands.

Synaccess Networks, Inc
QUICK STARTUP
REFERENCE

For netBooter™ series T or B Part # 1090 V10

How to start:

1) Use a straight-thru Ethernet cable connect

the unit to your network:
By default, DHCP is disabled. The static IP
address is 192.168.1.100. Use a WEB or Telnet
program to configure the unit. The default
ID/Password is admin/admin. If you need to enable
the DHCP, please read “DEFAULT SETTINGS”
section.

2) Use a crossover Ethernet cable to connect

to a PC directly:
The static IP address for the unit is 192.168.1.100.
Make sure your PC IP address is on the same
subnet. 192.168.1.x. Use WEB or Telnet program
to configure the unit.

3) Use a serial cable to connect the unit and a PC:

Run a Terminal Program on the PC to configure
the unit. The serial port settings are 9600-8-N-1.
Type command “help” or “?” to view a list of
command.

Synaccess Networks, Inc.

75 W. Baseline Rd. Suite 10

Gilbert, AZ 85233

(928) 257-1838 Fax-(760) 930-0550

www.synaccess-net.com

Page 1

Default IP: 192.168.1.100

DHCP is not enabled. To enable it, see Section
DEFAULT SETTINGS below.

Default serial port: 9600-8-N-1.

Using WEB browser to see more detailed system
configuration description.

For serial or Telnet interfacing, type command
“help” to see a list of commands.

Page 5

Page 6