Control / monitorization links’ server web server – Televes T.0X controlador CDC IP User Manual

Page 7

Advertising
background image

EN

7

Control / Monitorization
Links’ Server

Web Server

The CDC H/E Manager was designed to implement, through IP GSM-GPRS,

remote communication between any T.0X headend and the Client Control’s

Software. This can be done directly or through a Link Server that allows a plug-

and-play installation, thus not requiring any kind of IP network configuration.

Displays a list of devices that are connected to T0X BUS, and their status. Green

means that the T0X module is correct. Orange indicates that, at times, the

module has had incorrect states. Red indicates the module is in a bad state of

communication with the BUS.

Using the Web service you can perform an updating of the T.0X CDC remotely.

The figure illustrates the steps for its realization.

Both the Web server as CDC Software Server are also accessible locally to the

refs. 5559 and 555901.

The connection can be implemented on a LAN, or even directly over the

Internet, if you publish the output ports of CDC H/E MANAGER services.

The CDC Headend Manager allows local configuration through the LCD

programmer Ref. 7234.

The ref. 555901 has a Web server, which enables its settings. It allows visual

monitoring of the elements connected to the T.0X BUS.

Ref. 555901 enables IP communication either through Ethernet or via the GSM /

GPRS. Direct connections are also possible by either of the two networks.

The ref. 555901 can establish a data communication with the Link Server via

Internet, on the GSMGPRS network.

The GSM / GPRS provides fixed IP.

Links Server allows centralized management and monitoring of multiple

headends.

Management/Monitoring

CDC T.0X Headends

THE INTERNET

GSM/GPRS Network

T.0X headend

CDC H/E MANAGER

Direct communication. GSM or IP. (Ethernet or GSM/GPRS)
IP communication on GSM/GPRS
IP communication (Ethernet)

Central Server

Links/Services

Control by means of

an IP connection in a

LAN network with the

T0X CDC

PC software of

Control/Monitorization

Configuration of the T0X

CDC by means of the

programmer, ref. 7234

Outgoing communications: it

is not necessary to configure

the local IP network

Centralized management of

multiple headends

Security & Monitoring

Customizing for clients

Client

Fixed external IP

X.X.X.X

Fixed

logical

port

Televés S.A. Link Server

Link Server

Data Base

Logical ports assigned

to each customer

Client

Outgoing communications: it

is not necessary to

configure the

local IP network

INTERNET

Information Box

-Date/Time; CDC temperature.

- The name of this T.0X CDC module.

- Manufacturing serial number.

- Version of Software.

- Number of modules installed.

Homepage website CDC T.0X

Can be accessed by either

knowing the IP of its LAN, or

through the signaling fixed IP

which is always available:

http://:169.254.1.254:15706

The port is always:

15706

Main menu

Access to the headend’ status

Table showing T.0X

elements of the

headend, and their

status by colors.

MAIN: Main menu.

SCAN: it performs

a full checking of

the headend and

deletes existing

items.

RESET: Resets the

application with

the default values .

Correct

Identifying

Error

Confirmación

fichero

actualizado y

actualizado.

Advertising