ASSEMBLY

These models are furnished with wheels and
handles. Wheels, handles, and the mounting
hardware are found in the shipping carton.

TOOLS NEEDED

• Medium Phillips Screwdriver

• 3/8" Open or Adjustable Wrench

• Hammer

1.

Slide axle through wheel support
frame. Install wheels on axle.

IMPORTANT:

When installing wheels,

point extended hub of wheels toward
wheel support frame (see Figure 3).

2.

Place cap nuts on axle ends. Gently tap
with hammer to secure.

3.

Place heater on wheel support frame.
For D20N model, make sure outlet end
(front) of heater is over wheels. For
D30N and D44N models, make sure air
inlet end (rear) of heater is over wheels.
Line up holes on fuel tank flange with
holes on wheel support frame.

4.

For D20N model, place rear handle on
top of fuel tank flange. For D30N and
D44N models, place front handle and
rear handle on top of fuel tank flange.
Insert screws through handle(s), fuel
tank flange, and wheel support frame.
Attach nut finger tight after each screw
is inserted.

5.

After all screws are inserted, tighten
nuts firmly.

Figure 3 - Wheel and Handle Assembly

Handle

Sleeve Cap

Screw

Hot Air
Outlet

Air
Inlet

Wheel Support
Frame

Wheel

Fuel
Tank
Flange

Cap Nut

Nut

Extended
Hub

Axle

Screw

Wheel
Support
Frame

Wheel

Cap Nut

Nut

Extended
Hub

Front
Handle

Axle

Rear
Handle

Air
Inlet

Fuel
Tank
Flange

Hot Air
Outlet

D20N Model

VENTILATION

WARNING: Follow the mini-

mum fresh, outside air ventilation
requirements. If proper fresh, out-
side air ventilation is not provided,
carbon monoxide poisoning can
occur. Provide proper fresh, out-
side air ventilation before running
heater.

D30N and D44N Models

Provide a fresh air opening of at least 2800
square cm (three square feet) for each
100,000 Btu/Hr rating. Provide extra fresh
air if more heaters are being used.

Example:

A 150,000 Btu/Hr heater requires

one of the following:

• a two-car garage door [4.9 m (16 ft.) open-

ing] raised 9 cm (3.5 inches)

• a single-car garage door [2.75 m (9 ft.)

opening] raised 15.25 cm (6 inches)

• two, 76 cm (30 inch) windows raised 28

cm (11 inches)