United States Stove Company DV8 User Manual

Page 7

Advertising
background image

Clearance above grade, veranda,
porch, deck, or balcony

12 inches (30cm)

Clearance to window or door that may
be opened

6 inches (15 cm) for appliances <
10,000 Btuh (3 kW), 9 inches (23 cm)
for appliances > 10,000 Btuh (3 kW)
and < 50,000 Btuh (15 kW), 12 inches
(30 cm) for appliances > 50,000 Btuh
(15 kW).

Clearance to permanently closed
window

Vertical Clearance to ventilated soffit
located above the terminal within a
horizontal distance of 2 feet (61 cm)
from the center line of the terminal

Clearance to unventilated soffit
Clearance to outside corner.
Clearance to inside corner.

Clearance to each side of center line
extended above meter/regulator
assembly.

Clearance to service regulator vent
outlet.

Clearance to nonmechanical air supply
inlet to building or the combustion air
inlet to any building or other appliance.

6 inches (15 cm) for appliances <10,000
Btuh (3 kW), 9 inches (23 cm) for
appliances > 10,000 Btuh (3 kW) and <
50,000 Btuh (15 kW), 12 inches (30 cm)
for appliances > 50,000 Btuh
(15 kW).

Clearance to mechanical air supply
inlet.

Clearance above paved side walk or
paved driveway located on public
property.

Clearance under veranda, porch,
deck or balcony.

3 feet (91 cm) above if within 10 feet
(3 m) horizontally.

Canadian Installations¹

6 inches (15 cm) for appliances <
10,000 Btuh (3 kW), 12 inches (30
cm) for appliances > 10,000 Btuh
(3kW) and <100,000 Btuh (30kW), 36
inches (91 cm)for appliances >
100,000 Btuh (30kW).

3 feet (91 cm) within a height 15 feet
(4.57 m) above the meter/regulator
assembly.

6 inches (15 cm) for appliances < 10,000
Btuh (3 kW), 12 inches (30 cm) for
appliances > 10,000 Btuh (3kW) and
< 100,000 Btuh (30kW), 36 inches (91
cm) for appliances > 100,000 Btuh
(30kW).

6 feet (1.83 m)

7 feet (2.13m)

12 inches (30cm)

3 feet (91 cm)

3 feet (91 cm)

3 feet (91 cm)

12 inches (30cm)

2

Page 7

Advertising
This manual is related to the following products: