Vectronics VEC-884 User Manual
Page 49
Advertising

VEC-884 Owner's Manual
Advanced Features Error! Main Document Only.-9
Normal Jumper Settings Chart
JMP
1
JMP
2
JMP
3
Tone
Frequency
L L L 300
Hz
L L
H 400
Hz
L
H
L 500
Hz
L
H
H 600
Hz
H
L L *700 Hz
H
L
H 800
Hz
H
H
L 900
Hz
H
H
H 1000
Hz
JMP JMP
Code
4
5
Speed
L L *5 wpm
L
H
10 wpm
H
L
20 wpm
H
H 30
wpm
JMP
6
JMP
7
Auto Notch
Level
L
L
*1
L
H
2
H
L
3
H
H
4
* Factory defaults
This is what the jumpers should look
like for the following settings:
1000 Hz Talk pitch,
10 WPM Talk Morse code speed,
and Auto Notch level 1.
This is what the jumpers should look like
for the default settings:
700 Hz Talk pitch,
5 WPM Talk Morse code speed,
and Auto Notch level 1.
Advertising