Configuring Ports for Terminals and Computers

6-3

•

bps is the line speed

•

characters is the character size

•

parity is the parity scheme to use on this line

•

num-bits is the number of stop bits to use

3. If your terminal uses hardware flow control, supply a set flow command that specifies the fol-

lowing (software flow control is the default, so a set flow command is not required in that case):

set flow range=range ixoff=off ixon=off cts=on rts=on

where range is a port or range of ports

Note:

You may need to use additional set flow command fields, depending on the flow con-
trol scheme required by your terminal. See the set flow command in the Digi
One/PortServer TS Command Reference
for more information.

Example

In this example, port 1 and 2 are configured for connection to terminals using hardware flow control.
The connection uses default for character size (8 bits), parity (no parity), and stop bits (1).

set ports range=1-2 sess=3 dev=term termtype=wy60

set line range=1-2 baud=19200

set flow range=1-2 ixon=off ixoff=off rts=on cts=on

About Computer Connections

Configuring computer connections is very similar to configuring terminal connections, which is
discussed on page 6-2. Consequently, this section simply discusses the differences between these
connection types.

Starting Point

This section assumes that
•

You are logged in as root

•

You know the attributes, such as baud rate and parity, of the PC that will be connected to this
port

Configuring Typical PC Connections

To configure a port for a directly-connected PC, where the PC always initiates the connection,
configure the connection as you would a terminal connection, except on the set ports command do
the following:
•

Specify dev=min if you have a 10-pin null modem cable to support this type of connection.

•

Specify dev=term if you do not have a 10-pin null modem cable

Consider defining the serial connection as a PPP link. See "Configuring PPP" on page 8-1 for more
information.

Command Line Example

In this example, ports 1-2 are set up for a BBS host.

set ports range=1-2 dev=prn group=70

set line range=1-2 baud=19200

set flow range=1-2 ixon=off ixoff=of f rts=on cts=on

set altip group=70 ip=199.179.23.10