Web-based control application getting connected, Getting started, Have questions – Adtec digital RD-60 (version 1.13.02) Quick Start User Manual

Page 2

Advertising
background image

Adtec Digital Technical Support: 615.256.6619 www.adtecdigital.com

FW: 1.13.XX March 2015

Power .....................................................................................................................................
Power:

1 & 2 Redundant AC Power, Standard 3 pin computer power plug
(Auto range 70-240 VAC Input)

Processor ..............................................................................................................................
GigE:

MPEG2 or RTP multicast transport ingress port. Current Contraints: 1 - 100 Mbps

COM2:

API Serial Communication Interface

COM1:

Serial Port Used for Troubleshooting (Terminal)

Ethernet: 10/100 base T ethernet interface (Monitoring/Management)
RS422:

Not Currently Supported

Parport:

9-pin parallel I/O interface for control systems

GPIO:

Tally and Control Port

Decoder .............................................................................................................................
Analog Audio Out:

Balanced analog audio out. Stereo pairs 1 & 2

AES Audio Out 1-4:

75 Ohm AES-3 BNC

ASI In:

75 Ohm BNC

DVB-ASI x3 Out:

75 Ohm BNC

DVB-ASI In:

75 Ohm terminated. ASI Transport Stream Input

Sync In:

Standard analog video sync separation for NTSC, PAL, 480I/P, 576I/P, 720P, and 1080I/P/PsF from
Composite Video (CVBS). Bi-level & tri-level sync compatible. BNC

CVBS Out:

75 Ohm Standard Definition Composite Video Output BNC

SDI Out Banks:

(2) 75 Ohm Outputs from decoder: Video/Audio/VBI (SMPTE 259M-C - SD & SMPTE 292M - HD) BNC

Demodulator (optional)*......................................................................................................................
RF 1 & 2:

RF input, 75 Ohm F-Connector

Advanced (ADV) Model: Supports L-Band, DVB-S/S2, QPSK, 8PSK, 16APSK.
L-Band (LB) Model: Supports L-Band, DVB-S/S2, QPSK, 8PSK, 16APSK, 32APSK.
Premium (PRM) Model: Supports L-Band, DVB-S/S2, QPSK, 8PSK, 16APSK, 32APSK.
Standard (STD) Model: Supports L-Band, DVB-S/S2, QPSK, 8PSK 1-30 Mbaud.

Demodulator notes: Field upgradable demodulator keys are required to unlock full capability such as 16/32APSK. The STD demodulator has been discontinued.

Power

COM2

Demo

dulator

Processor

Deco

der

AES A

udio

In 1-4

DVC Par

por

t

RS422

GPIO

GigE

RF 1

RF 2

COM1

Ether

net

1

2

ASI O

ut X 3

DVB ASI I

n

S

ync I

n

CVBS O

ut

SDI O

ut

1 & 2

SDI O

ut

1 & 2

A

nalog

Audio 1

A

nalog

Audio 2

To begin, you will need to connect to your RD-60 via ethernet

directly, or by adding the RD-60 to your local area network.The default
address for all Adtec devices is 192.168.10.48.

To connect directly to the device, make sure that your computer

and the device have IP addresses within the same IP class range (ex.
192.168.10.48 for the device and 192.168.10.49 for your computer).
If you need to change the IP address of the device, this can be done via
the front panel, System > Network menu. Using a CAT 5 crossover
cable, connect one end to your computer and the other to the Ethernet
port found on the processor section of the back panel. (Some computers
can auto negotiate the connection and a crossover may not be
necessary.)

To add the device to a LAN, connect a standard Ethernet cable to

your network router and then to the Ethernet port on the back of the
device. If your network is DHCP enabled and you prefer that over a
static IP, you can turn on DHCP for the device via the front panel,
System > Network menu.

Web-Based Control Application

Getting Connected

Adtec Digital has adopted

zero-configuration networking
technology, streamlining the setup and
configuration processes for our products.
The use of this technology enables
automatic discovery of Adtec devices and
services on an IP network. Used in tandem
with the web-based control and
configuration applications we can now
provide 1-click access to any device.
By using the built-in Bonjour

©

locater in

Apple's

©

Safari

©

browser or the plug-ins

readily available for IE

©

or Firefox

©

browsers, users can locate all of the Adtec
devices on a network by referencing the

serial number on the back of the device. Clicking on the unit in the Bonjour

©

list will re-route you to a

login page. If you do not wish to use Bonjour, you can reach the device’s web application by pointing
your browser to the IP Address of the device. Ex. http://192.168.10.48/. You will be prompted for a
username and password. The default username is ‘adtec’. The default password is ‘none’.

The left-hand panel of the application will report current status in real-time while the right

panel tabs will allow you to configure your device.

?

Have questions?

Each field or group of fields in

our web-based application has a hint button associate
with it. It contains information on use of the field or
acceptable ranges.

Once your receiver is powered up, configured on

your network and you have inputs applied with active
services, you can select which services you want to
decode via the web-based control application. The below
image shows the Input > RD Services tab. From this tab,
you can view all services available on your device, select
one of the services for decode or view more details about
the service. There is a ‘Select First Found’ option for each
input. When selected, this configuration will detect the
first service detected in the PAT table of the input and
decode it.

Getting Started

Note: IP service selection is treated differently than ASI or RF
inputs. To populate the IP services section, you need to first
visit the IP Params tab and set the correct Multicast RX, port
and handling parameters. Return to the RD Services tab. Click
the ‘Select First Found’ radio button for IP. This will populate
the RD Services tab with services found on the IP input.

The most recent firmware releases are available on our
support website, www.adtecdigital.com. Advanced users can
find direct API command help as part of the on-board web
application, Help Tab.

Advertising