In-wall installation, Making good the wall – Amina ALF120 User Manual

Page 10

Advertising
background image

10

In-wall installation

Making good the wall

Cutting the outlet slot

Mark up the position of the outlet slot

•

using the dimensions shown in the
drawings below.
The slot must be 309mm wide x 15mm
tall, located on the centre-line of the
ALF120.

309mm

15mm

The bottom edge of the slot sits 18mm

•

above the stud under the ALF120.

Skirting

Cut a section of skirting (where used)

•

and repeat the process to cut a slot of
the same size in the same position.
Fit the skirting to complete the

•

installation.

Check that the slot aligns with the

•

opening at the base of the ALF120.
The wall can now be made good and

•

plastered.

18mm

Stud

height

height o

f s

tud

p

lus 18mm

16mm

15mm

14mm

Trim

Gasket

Port Plate

Felt Pads

Timber Stud

Skirting

Dry Wall

Advertising