Checking gas connections, Connecting to gas supply, Warning – Desa 14,000 User Manual

Page 21: Caution

Advertising
background image

21

101813

IMPORTANT:

Hold pressure regulator with wrench when connecting it to gas piping

and/or fittings.

CHECKING

GAS

CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply

piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.

Continued

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Test

Gauge

Connection *

Tee Joint

Pipe

Nipple

Cap

Sediment

Trap

Figure 25 - Gas Connection

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessories, page 34.

Pressure
Regulator

1/2" NPT
Pipe Nipple

Ground
Union
Joint

Heater
Cabinet

3" Minimum

Note:

Burner bracket

not shown for clarity

Manual
Shutoff
Valve *

From

External

Regulator

(11" W.C. to 14" W.C. Pressure)

CONNECTING

TO GAS

SUPPLY

Continued

WARNING ICON

G 001

WARNING

Test all gas piping and connections for leaks after installing or
servicing. Correct all leaks at once.

WARNING ICON

G 001

WARNING

Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.

WARNING ICON

G 001

CAUTION

Make sure external regulator has been installed between propane/
LP supply and heater. See guidelines under

Connecting to Gas

Supply, page 20.

Advertising
This manual is related to the following products: