Analog Way Eikos - EKS500 Programmer's Guide User Manual
Page 15
15
Group
Name
CmdResp Description
Read /
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_SYNC_TYPE
sK sK
Input sync type
Rd
0
3
0
0 = Séparated Synchros
H&V
1 = Composite TTL Synchro
2 = Composite Analog
Synchro
3 = Synchro on Green (SOG)
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_FREQ_FIELD
sf
sf
Input frame frequency
Rd
0
65535 0
Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_FREQ_LINE
sl
sl
Input line frequency
Rd
0
65535 0
Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_COMPLETE
sc
sc
Input scan completed
Rd
0
1
0
0 = scan in progress or
failed
1 = scan completed
0 = Input1
1 = Input2
2 = Input3