5

Group

Name

Cmd RespDescription

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

SYSTEM

DIESE

#

#

Request the retrieval of all the
variables

Rd/Wr 0

1

0

READY

*

*

Ready Device Flag

Rd

0

1

0

0= Initialization in progress
1 = Ready

DEV

?

DEV MMS device type

Rd

86

86

86

86 = EKS-400

CONTROLS

UPDATER

yU yU

Device reboot for update

Rd/Wr 0

255

0

1 then 254 => Reboot

FACTORYRESET

YR YR

Apply factory settings to the
device( except image settings )

Rd/Wr 0

1

0

Auto reset

POSMEMORYRESET

YE YE Erase stored image settings

Rd/Wr 0

1

0

Auto reset

CSTORE

YS YS

FLASH memory writing in progess.
Do not power off

Rd

0

1

0

0 = Free
1 = Flash writing in progress

LOCK

YK YK Device locking

Rd/Wr 0

2

0

0 = No lock
1 = Locked menu
2 = Locked front panel

LCDBRIGHTNESS

YB YB Front panel display brightness

Rd/Wr 1

8

8

1, …, 8 = Brightness level,
12,5% step

KEYBRIGHTNESS

Yb Yb

Front panel keys brightness

Rd/Wr 10

100

100

1, …, 100 = Brightness level,
1% step

TBAR_ENABLE

YD YD Enable disable T-BAR

Rd/Wr 0

1

1

COPKIND

CK CK Kind of slow in-progress operation Rd

0

6

0

0 = None
1 = Auto centering
2 = Auto setting
3 = StandBy
4 = Picture recording
5 = Reset to default factory
setting
6 = Reset User settings

COPPROGRESS

CP CP

Progress percent of the slow
operation

Rd

0

100

0

Percent : 0 to 100%

PRESET_MATRIX_MGMT

CR CR

Preset management in matrix mode
from the front panel

Rd/Wr 0

3

0

0 = Preset management for
both outputs
1 = Preset management for
current output
2 = Preset management for
output 1
3 = Preset management for
output 2

SWITCHER_MODE

CM CM Device operating mode

Rd/Wr 0

1

0

0 = Seamless switcher mode
1 = Matrix mode

Advertising